H3C 0235A14W S3100-26C-SI Ethernet Switch with 24 10/100BASE-TX ports and 2 module slots (DC -48V). Alternative name: LS-S3100-26C-SI-DC-OVS

Be the first to review this product

Condition: New
Packaging: Retail
UPC: 6934648004097

Availability: Out of stock

$715.00

Quick Overview

H3C 0235A14W S3100-26C-SI Ethernet Switch

H3C-0235A14W

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

Features

  • All the S3100-SI series switches employ full wire-speed switching to ensure their capability to forward packets fast even in a heavy load. They can provide 10/100 Mbps downlink and 100 Mbps/1000 Mbps uplink Ethernet ports.
  • The S3100-SI series switches support STP/RSTP/MSTP (Spanning Tree Protocol/Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol). The STP/RSTP features also support BPDU guard, Root guard, Loop guard, Edge-port and STP ignored per VLAN Thus the redundancy back-up and error tolerance capability of the link can be greatly improved to guarantee the network stability.
  • The S3100-SI series switches support STP/RSTP/MSTP (Spanning Tree Protocol/Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol). The STP/RSTP features also support BPDU guard, Root guard, Loop guard, Edge-port and STP ignored per VLAN Thus the redundancy back-up and error tolerance capability of the link can be greatly improved to guarantee the network stability.
  • The S3100-SI series switches support STP/RSTP/MSTP (Spanning Tree Protocol/Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol). The STP/RSTP features also support BPDU guard, Root guard, Loop guard, Edge-port and STP ignored per VLAN Thus the redundancy back-up and error tolerance capability of the link can be greatly improved to guarantee the network stability.
  • The S3100-SI series switches support STP/RSTP/MSTP (Spanning Tree Protocol/Rapid Spanning Tree Protocol/Multiple Spanning Tree Protocol). The STP/RSTP features also support BPDU guard, Root guard, Loop guard, Edge-port and STP ignored per VLAN Thus the redundancy back-up and error tolerance capability of the link can be greatly improved to guarantee the network stability.
  • The S3100-SI series switches support link-aggregation, it is a simple and cheap way to expand the bandwidth of a switch port and balance the traffic among all the ports in a link aggregation. Moreover, it enhances the connection reliability.
  • The S3100-SI series switches support Centralized MAC address authentication and user authentication at the local or with RADIUS servers that are based on 802.1x or its extension. 802.1x-based user authentications can be extended to dynamically assign a VLAN based on a specific user, regardless of where they connect on the network. With 802.1x with Guest VLAN, guests are allowed access the customer's internal network but cannot access to the Internet via the Guest VLAN.
  • The S3100-SI series switches support bidirectional port rate-limiting with the granularity of 64 Kbps, supporting finer bandwidth allocation. Port Mirroring is supported, when this function is applied, data packets on a mirroring port are copied to its monitor port for network test and troubleshooting.
  • The S3100-SI series switches support the queue scheduling algorithms of Weighted Round Robin (WRR) and High-priority Queuing + WRR (HQ+WRR).On a switch of the S3100-SI series, each port supports four output queues. The port flow control is used by the S3100-SI series switches to reduce congestion on the network.
  • The S3100-SI series switches support 3 priority criteria: IP-precedence priority, differentiated services code point priority (DSCP), and 802.1p priority. Customers can add packets to the output queue according to a priority criterion as needed.
  • The S3100-SI series switches can support SNMP v1/v2/v3 and can be managed by H3C iMC NMS. They also support CLI, Web network management, Telnet to facilitate the equipment management.
  • VCT (Virtual Cable Test) is supported, which is convenient for troubleshooting. Customers can start the VCT function to make the system test the cable connected to the current electrical Ethernet port. The test items include: whether short or open circuit exists in the Rx/Tx direction of the cable, and what is the length of the cable in normal status or the length from the port to the fault point of the cable.
  • After enabling HGMP V2, the network administrator can manage several member switches through one command switch and only the command switch need a public network IP address, it can save public IP address greatly and manage the network more efficiently.
  • S3100-16C-SI or S3100-8C-SI can be a standard POE powered device, there is no need to do creative power budgeting or adding an external power shelf, reducing the cost and complexity of IP Communications.
  • S3100-16C-SI, S3100-26C-SI and S3100-26T-SI are stackable, allowing network managers to build networks with high expansibility, high reliability and easy management.
  • "Pay as you go" is the slogan of the S3100-SI series switches, offering a cost-effective path for meeting current and future service requirements of customers.
  • The S3100-SI series switches support binding of MAC addresses and ports to prevent illegal users from accessing the network effectively. MAC address black hole function allows switch drops the packet when the switch receives a packet with a source or destination MAC address in the black hole. MAC address learning limit function limits the number of MAC addresses learned by an Ethernet switch port while the static MAC addresses added on the port are not affected.

Specifications

Fixed ports:24 10/100 BASE-TX ports
1 console port
Extended Slot:2
Extended Module: 10/100/1000BASE-T:max transmission distance: 100 m (328 ft)
100BASE-SX: SC connector, 2 km (1.24 mi)
100BASE-LX: SC connector, 15 km (9.32 mi)
100BASE-LH40: SC connector, 40 km (24.86 mi)
1000BASE-SX: SC connector, 0.5km (0.31 mi)
1000BASE-LX: SC connector, 10 km (6.21 mi)
1000BASE-LH40: LC connector, 40 km (24.86 mi)
1000BASE-LH70: LC connector, 70 km (43.50 mi)
1000BASE-STACK (not supported by S3100-8C-SI)
1000BASE-PX20(SC, 20km(12.4mi))
100BASE-LX-SM1310-BIDI(SC,15km(9.3mi))
100BASE-LX-SM1550-BIDI(SC,15km(9.3mi)
Switching capacity:8.8 Gbps
Switching Fabric:19.2Gbps
Throughput:6.55 Mpps
Stack (HGMP V2):Yes
Max stack numbers:16
Stack bandwidth (bps):4G
POE (As PD):No
MAC Address:Up to 8 K MAC addresses
Adding of dynamic/static unicast MAC address, multicast MAC address, and black hole MAC Address
Port Mirroring:Many-to-one port mirroring (that is, multiple mirroring ports, and one monitor port)
Remote switched port analyzer (RSPAN)
Port Features:Port isolation
Port self-loop detection
Port loopback (internal/external test)
VLAN:4k VLANs (IEEE 802.1Q)
GVRP (GARP VLAN Registration Protocol)
Port-based VLAN
QinQ
Link Aggregation:Support LACP
Up to 3 maximum aggregation groups (2 FE groups and 1 GE group), each containing up to 8FE/2GE
Traffic control:IEEE 802.3x full-duplex flow control
Port bandwidth percentage-based Broadcast storm suppression
STP/RSTP/MSTP:IEEE 802.1D Spanning Tree Protocol (STP)
IEEE 802.1w Rapid Spanning Tree Protocol (RSTP)
IEEE 802.1s Multiple Spanning Tree Protocol (MSTP)
Multicast:MVR(Multicast VLAN Registration)
256 Multicast groups
IGMP snooping
Network protocol:DHCP Snooping
QoS(Quality of Service):Four output queues on each port
Support flexible queue scheduling algorithms: WRR, HQ+WRR
Drop of unknown multicast packets
Security Features:SSHv2
Guest VLAN
MAC Black Hole
Centralized MAC Address Authentication
Hierarchical user management and password protection
Port-based and MAC-based 802.1X authentication
Support AAA/RADIUS /HWTACACS authentication
Local authentication server
Management and maintenance:Support CLI (Command Line Interface) configuration mode
Support Configuration via the console port
Support Local/remote configuration via Telnet
Support System configuration with SNMP v1/v2/v3
Support RMON (Remote Monitoring) v1 1, 2, 3 and 9 groups of MIB
Support H3C iMC
Support WEB management system
Support Hierarchical alarms
Support System log
Support NDP (Neighbor Discovery Protocol)
Support NTDP (Network Topology Discovery Protocol)
Debug information output
Ping, traceroute, multicast traceroute
Remote maintenance through Telnet
VCT (Virtual Cable Test)
Maximum system power consumption: 20W
Input voltage: AC input for AC-powered switches.:br />Rated voltage range: 100V~240V, 50/60 Hz
Max voltage range: 90V~264V, 47~63 Hz
DC input for DC-powered switches:
Rated voltage range: -48V ~ -60V
Max voltage range: -36V ~-72V 